it could also be a failing breaker, but that would be a last resort. Hi. PF1202T Freeze Protection Control Home Pool Parts Time Clock & Control Parts PF1202T Freeze Protection Control Ideally, the switch would be placed after the timeclock, not before. 1100 Juanita St , Austin, TX 78704-5351 is a single-family home listed for-sale at $2,649,000. Intermatic time clocks are the workhorse of your pool equipment collection, and oftentimes outlive the equipment they control. Please advise. You will first want to look at the pool timer and see if you have two timer pins. You can check these easily by removing them and inspecting them for damage. It is a good idea to use pliers or a wrench and reseat the trippers, then tighten them at the desired on/off times. Check the diagram on the box label, and connect the wires from the breaker to the terminals marked Line, and the wires that go to the pump connect to the terminals marked Load. Motor runs past the on dog but doesnt flip pump on? MLS # 6354744 Ive got a weak pump battery so every time the mechanism shuts off it looses time. 2. Any advice? Read Book Tork Trippers Manual Guide Pdf For Free Sea Kayaking The World Almanac Road Trippers' Guide to National Parks: 5,001 Things to Do, Learn, and See for Yourself Dream Trippers The Little Road Trip Handbook Technical Manual War Department Technical Manual Canadian Mining Journal. No broken or loose wires visible. Sometimes during power surges or lightning, these will be fused together and not come apart. Check that the breaker is firmly pushed onto the bar, and is not loose. Hi Phil, usually the OFF dog may not be fully pushed onto the dial, or if you examine it closely, it might be worn. If none of the above suggestions resolves your issues or the issues continue to persist, it may be a good idea to purchase a new Intermatic timer for your pump. Hi Casey, perhaps the cord or wires are broken? During this the pump cannot be manually switched on. Grab your torch and shine it in the holes. If you cant, is the manual switch stuck or jammed? Ft. 750 Joshua Dr, Hollister, CA 95023. Timer must be reset for current time after power outage. You can replace it but its really just easier to replace the entire mechanism. DEWENWILS Outdoor Outlet Box. Does the manual lever stay in the on position always? But no gears or any sound. Any guidance on how to fix this? That was probably what burned the plug. No Power to the Timer Having no power to your pool timer is a common problem and will occur because of three reasons: The Circuit Breaker has tripped. I dont see timer gears rotating on any power going to the pump or salt system. I cant seem to find the exact replacement for this timer on the web and wanted to ask if you knew which intermatic pool timer model would match the one I have. Take a good look at the position of the pins and write down the locations. Then remove the mechanism by pressing the clip at the top of the timer box. "publisher": {
Hi Davy, What is the problem? This will cause issues such as the pump not switching on or off to the pump turning on or off at incorrect times. "width": "611",
It worked for a day but the day after it didnt work. But if your circuit breaker is in the on position and your pool timer clock is not rotating and the timer is not working then you will need to call a licensed electrician to replace the timer. Terminals 2 and 4 are used for wires going to the load (pump). Help! After securing the wire conduit (flexible or rigid) to the box, knock out with the proper 3/4 conduit connector. The problem was the connections I made inside my main electrical panel, I used romex wire nuts to attach the solid core #10 wire that I used to hook up the timer to the existing stranded #10 wire and it didnt make the connection so to speak. My intermatic timer is not turning my pool pump on. It just seems to have a weak start?? Does the motor gradually start running slowly? Look into the visual motor check window, near the top of the timer mechanism. Is there a control board, PCB in the panel that could have problems? My timer clock does not run and the manual on off switch does not turn off the pump motor. Most Intermatic timer parts can be renewed but sometimes you need to replace the whole mechanism. If its loose, grab a screwdriver and tighten it up. I have three outlets going out one to the pump , one for the salt system and one for the GFCI outlet. Miriam, I would check that the timer dogs are pushed fully onto the dial, and the dial is tight also check the screw for tightness in the center of the dial. 110V or 220V? Is it Necessary? "author": {
Once you have the timer set to the correct time you then can loose the little hold down screw on both the timer on and timer off pins. "logo": {
Look to see if the clock is set to the correct time. Hi Dave, my pool timers not working but when I look in the little window I do see the largest back gear turning (possibly the yellow time plate gear as that appears to be moving..yet not keeping correct time.) The 2,810 sq. Also be sure that the dial is not pulled out, but is engaging the gear behind the dial. Can A intermatic timer for a pool be lubricated I have duel timers for a low and high speed jandy pumpIt seems it might be a little louder on the fast speed side. Check that the TEST button has not popped out. Does the tripper work on other areas of the clock, like near the off tripper? Replace the gears if this is an issue. Rich. The rest of your setup is probably fine. Yet another reason why timers dont work properly is the yellow clock wheel is not located or seated properly. Watch these tips and tricks before replacing it. Does this give you a better idea of the problem? Sometimes the on/off switch on Intermatic and other mechanical timers can get tight. These clocks determine when your pool pump turns on, and how long it runs. These are the trippers that came with the time clock. Only perform this step if you are qualified. "@type": "ImageObject",
The mechanism for the off tripper doesn't work at all when manually depressed. "width": "611",
Any suggestions? If it continues and cant find solution, suggest replacing timer motor, or entire mechanism. do i need to do something different? It is a mechanical issue between the trippers and the switch lever. Still no luck. Electrical Monke Aug 25, 2021 #22 It's broken. More. I made sure the trippers were fully inserted and tight. I see a little groove worn in the corner of the on/off switch where the off timer dog touches. I didnt check the connections because it seemed like an ordeal to take the timer apart to get to the wiring and I didnt want to make matters worse. Is it Necessary? Or might find something else. This site is owned and operated by AJH Trade Group. Because a pool timer is an electrical timer with mechanical aspects, the clock dial portion of the timer pulls out to set the time. The instructions say THIS TIMER IS NOT TO BE USED AS A POWER DISCONNECT. My pool pump and skimmer are on two different motors. I have a sweeper set on auto on the second timer and it is working correctly. If you look closely (with a flashlight and your glasses! "description": "Frequently asked questions about Intermatic T104 and T101 timeclocks, used to power many loads, and the primary timer used for swimming pool pumps in America. what causes timer on/off pins to bend and how can i prevent timer pins from bending. On mine, the gears behind the dial look metal, but the motor (behind the plate) they look plastic (maybe?) The freeze protection on your clock, the probe may be bad or malfunctioning, and may be turning off the pump. Partially loosen the screw that holds the "off" pin in place. Do not remove the screws from the trippers. If there is still no movement, test the wires coming into the time clock to see if power is reaching the time clock. 1-48 of 242 results for "pool timer trippers" RESULTS. Switch the breaker off at the power board. 1. It is still moving and it will trip off but not on. If the clock was already showing the correct time, check the On/Off Trippers (Pointers) are set to the correct time and are not loose. The clock will also be missing 3-hours of time, so will need to be reset to the current time. "address": "",
Thanks in advanced. Terry, unusual but check all connections, making sure that bare wire is tightly contacting the terminal screw plates. Timer not tripping pump on. Or if power is interrupted to the pool pad, for some reason, maybe breakers flipped off for some electrical work? Hi, new timer out of the box, 200V. Once you remove the water, you can use your pool brush on a pole, to gently push the pillows back to the center. how do I check the manual over ride switch to see if it is off? Posted by 4 years ago. Flip it from where it is now, to the opposite side. For additional tripper pairs on CLOCK-DIALorder 156T1978A. Ive seen it happen from lightning strikes, or insect infestation. Thank you, I dont know about the box, was just told the mechanical timer a T104 is needed. DEWENWILS Pool Pump Timer, Digital Timer Box, 2HP 40A 120-277 VAC, 7-Day 20 ON/Off Programmable Timer Switch for Water . Look for any disconnected or damaged wires leading to the motor on the rear of the clock. Spray WD-40 or any kind of lubricant onto the manual lever to loosen it. "@type": "ImageObject",
Proceed to step 4 to check the timer itself. Hi Agnes, have you tried using a cover pump to remove the rain and/or snow melt from the cover? The A terminal is not normally used, unless you have a 3 wire service. No matter what caused the issue, there is typically an easy fix! There is a lot of water that is making the cover sink and I dont want to keep filling the pool with water trying to get the cover up/. You can find this in your power board. Take them off and inspect them. Leave the paper inside your timer box so that you do not mistakenly misplace it. Is this a bad timer mechanism or loose wire? I have a 2 speed pump. We like that this pool timer because it is made from heavy-duty material and two grounded outlet makes it safe and durable. how should I lubricate those? Clock not turning or making any sound. If I manually flip the switch nothing happens. A wire inside the motor may be touching another wire, or the metal sides of the motor. Put a meter on the wires or trace them back to find out their voltage and source. The most common pool timer used for inground pool pumps is the Intermatic time clock. Hi Bev, seems legit to me! It is twisted clockwise or counterclockwise until the correct current time lines up with the "Time" marker, which points directly downward at all times while the clock dial constantly turns. I had the exact same thing happen recently. I had to order new trippers as mine have been straightened too many times. TO SET "ON" AND "OFF" TIMES: Hold trippers against edge of CLOCK-DIAL, pointing to time (AM or PM) when ON and OFF operations are desired, tighten tripper screws firmly. The green tripper is a recent thing - maybe the last 3 years they have been included in the replacement bag. Pool Timer Not Turning ON or OFF!! Also check that the motor number is compatible with your clock model. It is an ON tripper right? Same way, WD-40 or any light lubricating oil. Sometimes the circuit breaker will trip again as soon as you reset it or even trip when the pump starts running. I would shut off power to the clock while you spray, and release the tab at the top so you can spray behind the clock, and then find the nearby nest, and dig it up and add in some ant killer granular, or other method, to get the colony to move somewhere else. Hi Chad, the trip mechanism on the clock, the switch, could be worn to the point where the tripper does not make good contact. If all looks well, and the gears are still not turning, you may need to replace the mechanism. "dateModified": "1/10/2020",
but ythe costs for T104 models vary greatlyHave ahayward 1 1/2 horsepower pump inground pool in Fl. {
There should be an off pin and an on pin. You could be missing the timer pins, you could have a bad timer, you could have no power to the timer or maybe even the timer is set wrong and it really is working but your not seeing it. If the switch simply does not move side to side, it may be a bad clock, if you cannot see what is stopping it from moving. Intermatic timers are a great addition to your pool set up but they can go wrong. Tighten down all brass screws securely, to hold all wires firmly in place. How can it keep time if lever is in off position (manual lever). Either that or if an older clock, the motor may be failing, or the switch mechanism worn (the part that is tripped by the tripper). The position of the metal bar forces the gear next to it to turn one way or another. Hello, newer pool guy here. Are the gears engaged, in the center, behind the dial? I have replaced my pool timer 3 times in the last week and they will work for a day then quit working any idea what the problem could be? So I connected all leads as on the directions and the clock and on off manual switch working.Not sure if timer was never connected or someone disconnected it. If the power has gone out, your just opening your swimming pool for the season or some third reason, you may need to adjust the time on your Intermatic swimming pool timer. My timer works good it turns on and off when I set the time. But if the timer doesnt come back on after a storm, there could be an issue. I went to the control panel and saw that the timer needle stopped just after the start pointer. I have a intermatic T101 and the clock doesnt move I replaced the old one due to burned out motor . You can turn off Freeze protection and it should stop, or replace the probe if faulty. This page is fantastic!! Before using your timer to optimize your pump, you need to determine that your pool's pH, alkalinity, and calcium hardness are 7.4 to 7.6, 100 to 150 ppm, and 150 to 400 ppm, respectively. "@type": "Person",
I flicked the switch between on and off and it will not shut off. Is the dial bent or warped? If you need to set the time, you will need to take two fingers and slightly pull the wheel towards you and away from the back of the timer box. Any ideas? Inspect the tripper portion, if it looks rounder or worn, replace them. The timer not working is for the pump. I have a white, red, and black wire coming from the power source. Theres really only 3 causes as to why your pump wont turn on/off. There is a second switch between the breaker and the timer. Hello. Thank you. Hello. I bought new trippers. I am having the same problem. Any idea what may be causing this? I would check that the motor says 60 hz on it and they did not send you a 50 hz by mistake. How can I fix this? The time is in my workshop and i normally sit next to it all the time so i know its noisier but its still working fine. But first, pull the mechanism from the box by releasing the tab at the top (be sure breaker is turned off, first), and inspect the gears and copper tabs on the back, to look for something clogging up the works, insects, lizards, sand, etc. The timer switch has a solid click between trying to turn it on and off but since no power is going to the timer I get no juice tot he motor. I noticed that they had stopped. Yes, seen that before! "image": {
It is a dayton time switch model 2E259 with switch rating of 40 amps, 2 HP, 250 volts AC with clock motor rating of 250 volts and 60 cycles. Pull the timer out and turn it to the correct time. You will feel the wheel pull out about an 1/8 of an inch and then you will be able to rotate the timer wheel. If your Intermatic swimming pool timer has stopped working you will have to do something called troubleshooting. the problem lies, where the power dies as they say. Sometimes we suspect the timer is the issue but it turns out its really the pump or the wiring between the pump and the timer. This product is certified by Amazon to work with Alexa. You need extreme care in this next step. Is it toast ? i have a P1121 intermatic timer connected to a hayward above ground pool pump. All Rights Reserved. It started lagging again a week or so ago. So either the tripper is broken (or installed out of alignment) or the tab (s) on the on/off switch are broken. Another time clock that you can plug your pump directly into, and then plug the timer into the outlet, is the 24-hr Timer https://www.intheswim.com/p/24-hour-pump-timer (currently we are out of stock, but you can find at any home or hardware store). 3. Many thanks! 120Volt Tork 1101 timers can be fixed with repair parts. Hi John, the trip mechanism on the clock, the switch, could be worn to the point where the tripper does not make good contact. Also be careful not to loosen the timer pins to much or they could fall off the timer wheel and onto the ground. Followed all directions and even watched YouTube troubleshooting videos. If you have gone back after a few hours and the pins have moved that means you have electrical power to your timer and it is working. If youve followed this guide or arent confident in diagnosing the issue yourself, seek a qualified pool technician or electrician. Hello Davy, Terry here again. To check this, carefully inspect the gears for missing teeth and make sure they all freely turn. You can replace the timer motor only, or the entire clock, both fairly easy to swap out. Check out our online selection of new Intermatic timer clocks at InTheSwim.com! You will have live wires exposed and they can kill you if you touch them. First time pool owner, Pool timer and trippers not working properly! If the trippers are loose, then they could slip and cause issues with the pump turning on/off at the correct times. The 120V or the T101 model has 3 brass screws (terminals) underneath the plastic insulator cover. Move the start and stop pins to appropriate times for swimming pool filter operation. I have a inground pool with T10003RT4 control panel. "url": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide"
I would suggest calling Intermatic and suggesting that idea and a free replacement? What Im wanting to do is just disable the turn off/on and just keep power 24/7. How about the GFCI outlet TEST button, is it tripped? Replace the plastic insulator cover, turn on the power, and observe the visual motor check. I have an Intermatic t104. Back when I was a young technician I was taught to always look for the easy things and use all my senses. I found a diagram showing neutral to A, line 1 to terminal 1 and line 2 to terminal 3. When you flip the switch does it separate and reconnect the tabs? Common timer problems include the clock not turning, not switching the pump on/off, loose timer pointer and a stopped clock. Hi Jere, that could be the timer motor failing. So out comes the soldering gun and the shrink wraps and that did the trick. The dial turns, but when it gets to the trippers, both now, the dial stops & there is no sound the gears are working I am not an electrician but I can do small repairs. Intermatic timers are common among pool owners and typically last a long time, but they also can come with problems and may need to be fixed. Wont power on pump but can hear timer clicking away. Pool pump comes on fine with the on dog, but wont turn off. Pool and Spa Expert: Mike_G2010 With the switch up it is in Auto mode. Intermatic time clocks are the workhorse of your pool equipment collection, and oftentimes outlive the equipment they control. Push down on the timers until they snap into place. It stays on until I turn off the circuit breaker. If you dont have the voltage here you have an issue with either the wiring or the breaker. Tracing the power it goes from breaker to control panel, and then to the time clock, then to the pump. Any advice on how to fix. There are 2 main facets to setting the mechanical timer for a pool pump, setting the time, and setting the on/off trippers. I copied the wiring config exactly and my clock gears still arent moving, so now Im thinking the wiring was wrong all along. Just replace it and hope for one that isnt defective. I have to reset the time every day. If you cant see an issue with the gears, then it could be the timer motor. "name": "Davy Merino",
So just turn the adjustment hold down screw on the timer pin counter clockwise about a full turn and then you will be able to slide the on or off pin to the right time on the timer wheel. Pool co says T104 timer needs replacement and filter cartridge. To reset the time clock to the correct time, grasp the outer edges of the large yellow dial, and pull gently outward. This is the first step to confirm if there is power or not. I have an intermatic timer thats 2 years young. You most likely just need to now set the pins and the clock and your timer will work. Problems with Intermatic timers are caused by defective trippers, incorrect wiring, tripped circuit breakers, a faulty time clock motor and incorrectly set power terminals. I have an intermatic T20004R and my timer is working because it is keeping the correct time. Since it came out of the box today, it probably is not trash in the gears.It seems the plastic gears and/or the coil in the clock mechanism are not strong enough to engage the on/off points or not for long. Basically 12 real life hours equals about 14 on the timer. Thanks. You can turn that yellow dial by hand CW to see if the trippers hit the off and on switch and to set the time on it. We are on our third timer. Can I spray the timer while there is electricity going in the timer box? sometimes Im forgetful lol what are your thoughts? You can manually engage it by turning it and then it will run and even SHUT OFF when its supposed to.
Neshaminy High School Teachers, Draught Beer Is Classed As Pre Packed Food, Articles P